YATO TRUE RMS LCD Multimeter 19999

Official YATO Dealer
- 100% genuine products
- Manufacturer warranty
- Professional consultation
Technical Specifications
Dimensions: 180 x 90 x 45 mm
Material: ABS
Application: Electrical work
Operating temperature range: 0–40 ˚C
Storage temperature: -10 to +50 ˚C
Power supply: Battery
Battery type: 2 x 1,5 V; AA
Weight: 0,319 kg
Display type: LCD
Reading hold: Yes
Circuit continuity test: 0–50 Ω
Conductivity test: Yes
LED backlighting: Yes
Front light: No
Relative humidity during operation Rh: <75%
Low battery indicator: Yes
Fuse: F200mAL250V / F20AL250V
AC voltage: 0–750 V AC
DC voltage: 0–999,9 V DC
DC current: 0–19,999 A
Resistance: 0–199,99 MΩ
Diode test: Yes
AC current: 0–19,999 A
Capacitance: 0–9,999 mF
Frequency: 0–9,999 MHz
Temperature: -20 to +1000 ˚C
Sampling rate: 3 times per second
TRUE RMS: Yes
Automatic measuring range selection: Yes
Maximum value recording: Yes
Duty cycle: 1–99%
Minimum value recording: Yes
Relative value measurement: Yes
Audible signal: Yes
Display count: 19999
Automatic shut-off: 15 min
Non-contact AC voltage detection NCV: Yes
The YATO TRUE RMS LCD Multimeter 19999 is a universal measuring device for measuring electrical quantities. Its TRUE RMS function helps determine the true RMS value of AC voltage and current.
It is suitable for electronics technicians, electricians and home measurements.
The large multifunction LCD display and measurement-enhancing functions make it easy to use.
Measurements and measuring range selection
The device can measure AC and DC voltage and current, resistance, capacitance, frequency, duty cycle and temperature.
It can also test diodes and circuit continuity, and detect AC voltage without contact.
TRUE RMS displays the true RMS value of AC voltage and current.
Unlike devices that measure the average value, it gives an accurate result for sine waves as well as distorted sine, square and triangular signals.
This function is useful, for example, when measuring switch-mode power supplies, motors driven by frequency converters and HVAC systems.
Automatic measuring range selection finds a suitable range for the measured value in a single measurement.
The device starts in automatic range mode, but the range can also be selected manually if needed.
Manual selection can speed up consecutive testing of many components with the same value, such as resistors.
Non-contact detection and measurement-enhancing functions
The NCV function inductively detects the presence of AC voltage in an insulated wire.
The detection sensor is located on the front of the device.
The SELECT button switches between measurement modes, for example from AC voltage measurement to DC voltage measurement.
In frequency measurement mode, the HZ % button switches the measurement mode to duty cycle measurement.
The REL function sets the displayed reading as a reference value, and the next measurement displays the difference between the measured and stored values.
MAX/MIN keeps the highest or lowest measurement value on the display.
DATA HOLD retains the current reading.
Diode testing and circuit continuity testing can be selected separately; the continuity test emits an audible signal for resistance below 50 Ω.
Measurement accuracy example
AC voltage measurement example: for a reading of 235 V, the accuracy in this range is ±(0,3% + 3) and the resolution is 0,1 V.
Calculation: (235 × 0,3%) + (3 × 0,1) = 0,705 + 0,3 = 1,005 V.
Therefore, for a reading of 235 V, the actual value is 235 ± 1,005 V within the measurement error.
For a DC voltage reading of 12 V, the result is 12 ± 0,009 V, and for an AC current reading of 8 A, it is 8 ± 0,067 A.
The table of measuring range resolutions and accuracies is provided in the user manual.
Housing and test leads
The ABS housing is equipped with a red rubber protective cover that helps you hold the device and reduces the risk of damage if it is dropped.
The cover has separate slots for the test probes.
The flexible silicone insulation of the test leads withstands high temperatures.
An immersion temperature probe is included for temperature measurement.
The device has overload protection, display backlighting and a low battery indicator.
After 15 minutes of inactivity, the device switches off automatically; the automatic shut-off can also be disabled.
Two 1,5 V AA batteries are required for power.
Dimensions: 180 x 90 x 45 mm
Material: ABS
Application: Electrical work
Operating temperature range: 0–40 ˚C
Storage temperature: -10 to +50 ˚C
Power supply: Battery
Battery type: 2 x 1,5 V; AA
Weight: 0,319 kg
Display type: LCD
Reading hold: Yes
Circuit continuity test: 0–50 Ω
Conductivity test: Yes
LED backlighting: Yes
Front light: No
Relative humidity during operation Rh: <75%
Low battery indicator: Yes
Fuse: F200mAL250V / F20AL250V
AC voltage: 0–750 V AC
DC voltage: 0–999,9 V DC
DC current: 0–19,999 A
Resistance: 0–199,99 MΩ
Diode test: Yes
AC current: 0–19,999 A
Capacitance: 0–9,999 mF
Frequency: 0–9,999 MHz
Temperature: -20 to +1000 ˚C
Sampling rate: 3 times per second
TRUE RMS: Yes
Automatic measuring range selection: Yes
Maximum value recording: Yes
Duty cycle: 1–99%
Minimum value recording: Yes
Relative value measurement: Yes
Audible signal: Yes
Display count: 19999
Automatic shut-off: 15 min
Non-contact AC voltage detection NCV: Yes
Returns & Warranty
Product returns
14-day right of withdrawal. Terms for consumers and business customers.
Return instructionsWarranty
All products come with manufacturer warranty as required by law.
We ship from Estonia






Delivery time depends on stock
This product has no reviews yet. Be the first to rate it.
Product description
The YATO TRUE RMS LCD Multimeter 19999 is a universal measuring device for measuring electrical quantities. Its TRUE RMS function helps determine the true RMS value of AC voltage and current.
It is suitable for electronics technicians, electricians and home measurements.
The large multifunction LCD display and measurement-enhancing functions make it easy to use.
Measurements and measuring range selection
The device can measure AC and DC voltage and current, resistance, capacitance, frequency, duty cycle and temperature.
It can also test diodes and circuit continuity, and detect AC voltage without contact.
TRUE RMS displays the true RMS value of AC voltage and current.
Unlike devices that measure the average value, it gives an accurate result for sine waves as well as distorted sine, square and triangular signals.
This function is useful, for example, when measuring switch-mode power supplies, motors driven by frequency converters and HVAC systems.
Automatic measuring range selection finds a suitable range for the measured value in a single measurement.
The device starts in automatic range mode, but the range can also be selected manually if needed.
Manual selection can speed up consecutive testing of many components with the same value, such as resistors.
Non-contact detection and measurement-enhancing functions
The NCV function inductively detects the presence of AC voltage in an insulated wire.
The detection sensor is located on the front of the device.
The SELECT button switches between measurement modes, for example from AC voltage measurement to DC voltage measurement.
In frequency measurement mode, the HZ % button switches the measurement mode to duty cycle measurement.
The REL function sets the displayed reading as a reference value, and the next measurement displays the difference between the measured and stored values.
MAX/MIN keeps the highest or lowest measurement value on the display.
DATA HOLD retains the current reading.
Diode testing and circuit continuity testing can be selected separately; the continuity test emits an audible signal for resistance below 50 Ω.
Measurement accuracy example
AC voltage measurement example: for a reading of 235 V, the accuracy in this range is ±(0,3% + 3) and the resolution is 0,1 V.
Calculation: (235 × 0,3%) + (3 × 0,1) = 0,705 + 0,3 = 1,005 V.
Therefore, for a reading of 235 V, the actual value is 235 ± 1,005 V within the measurement error.
For a DC voltage reading of 12 V, the result is 12 ± 0,009 V, and for an AC current reading of 8 A, it is 8 ± 0,067 A.
The table of measuring range resolutions and accuracies is provided in the user manual.
Housing and test leads
The ABS housing is equipped with a red rubber protective cover that helps you hold the device and reduces the risk of damage if it is dropped.
The cover has separate slots for the test probes.
The flexible silicone insulation of the test leads withstands high temperatures.
An immersion temperature probe is included for temperature measurement.
The device has overload protection, display backlighting and a low battery indicator.
After 15 minutes of inactivity, the device switches off automatically; the automatic shut-off can also be disabled.
Two 1,5 V AA batteries are required for power.
Shipping & Delivery
We ship from Estonia






Delivery time depends on stock
Returns & Warranty
Product returns
14-day right of withdrawal. Terms for consumers and business customers.
Return instructionsWarranty
All products come with manufacturer warranty as required by law.
Reviews