Technical Specifications
Dimensions: 194 x 75 x 35 mm
Material: ABS
Application: electrical work
Operating temperature: 0–40 °C
Storage temperature: –10 to +50 °C
Power supply: battery
Battery type: 3 × 1,5 V; AAA
Weight: 0,2 kg
Display type: LCD
Measurement hold: yes
Continuity test: 0–50 Ω
Conductivity test: yes
LED backlight: yes
Front light: yes
Relative humidity of the operating environment Rh: <75 %
Low battery indicator: yes
AC voltage: 0–750 V AC
DC voltage: 0–1000 V DC
DC current: 0–1000 A
Resistance: 0–60 MΩ
Diode test: yes
Battery test: yes
AC current: 0–1000 A
Capacitance: 0–100 mF
Frequency: 0–10 MHz
Temperature: –30 to +1000 °C
Sampling rate: 3 times per second
TRUE RMS: yes
Automatic measurement range selection: yes
Maximum clamp opening width: 25 mm
Maximum diameter of cable measurable with the clamp: 25 mm
Beep: yes
Display range: 6000
Automatic shutdown: 15 min
Non-contact AC voltage detection NCV: yes
Measured peak value hold mode: yes
The YATO TRUE RMS clamp multimeter YT-730933 is a measuring instrument designed for basic and precision measurements of electrical quantities. Its clamp can be used to measure AC and DC current from 10 mA–1000 A.
There is no need to interrupt the circuit or disconnect it from the power supply to measure current, and the clamp can measure higher current than conventional electrical measuring instruments.
The clamp must be closed around a single core or wire; closing it around a multicore cable without separating the cores may give an incorrect or zero reading.
Measurement capabilities
The device measures AC and DC voltage, AC and DC current, and resistance. It can also measure capacitance, frequency and temperature, perform a diode test, and check circuit continuity. The diode test current is IF 2 mA and the reverse voltage is UR 3,2 V. The device can also measure inrush current and detect phase.
TRUE RMS and DC measurement
TRUE RMS displays the true RMS value of AC voltage and current.
It provides a reading for sine waves as well as distorted sine, square and triangular waveforms.
This function is necessary, for example, in circuits with switched-mode power supplies, motor drives with frequency converters, and HVAC systems.
The TRUE RMS frequency range for AC voltage and current measurement is 40–1000 Hz.
For DC current measurement, the device uses a Hall sensor that measures magnetic field strength.
The Earth's magnetic field may cause a non-zero initial reading; use the REL button to zero the reading.
Voltage detection and measurement range selection
NCV detects AC voltage inductively and without contact, making it possible to detect voltage in an insulated wire and helping to identify the phase wire.
The LINE function detects AC voltage by contact, like a conventional voltage tester.
If the probe is inserted into an outlet opening and a phase is present, four dashes appear on the display, the indicator light turns on, and an intermittent beep sounds.
AUTO selects the measurement range automatically and is the device's default startup mode.
When measuring an unknown value, the device finds the appropriate range in a single measurement.
The RAN function allows the range to be changed manually.
When selecting the range manually, start with the highest range and work down to a more precise one, as selecting the wrong range may damage the device.
DATA HOLD keeps the measured value on the display.
Inrush current and measurement accuracy
The INR function measures inrush current with the clamp 80 ms after the device starts up.
Examples of measurement results with uncertainty: for an AC current reading of 30 A, 30 ± 0,85 A; for an AC voltage of 235 V, 235 ± 2,85 V; and for a DC voltage of 12 V, 12 ± 0,146 V.
The table of measurement range resolution and accuracy is in the user manual.
Display and construction
The display shows measurement results, and the probe leads have flexible, high-temperature-resistant silicone insulation.
The probes are 14 cm long, the lead length including the probes is 103 cm, and the lead diameter including insulation is 3,6 mm.
During the continuity test, a beep sounds when the resistance is below 50 Ω.
A storage bag is included.
The device has overload protection, and automatic shutdown can be disabled if desired.
Dimensions: 194 x 75 x 35 mm
Material: ABS
Application: electrical work
Operating temperature: 0–40 °C
Storage temperature: –10 to +50 °C
Power supply: battery
Battery type: 3 × 1,5 V; AAA
Weight: 0,2 kg
Display type: LCD
Measurement hold: yes
Continuity test: 0–50 Ω
Conductivity test: yes
LED backlight: yes
Front light: yes
Relative humidity of the operating environment Rh: <75 %
Low battery indicator: yes
AC voltage: 0–750 V AC
DC voltage: 0–1000 V DC
DC current: 0–1000 A
Resistance: 0–60 MΩ
Diode test: yes
Battery test: yes
AC current: 0–1000 A
Capacitance: 0–100 mF
Frequency: 0–10 MHz
Temperature: –30 to +1000 °C
Sampling rate: 3 times per second
TRUE RMS: yes
Automatic measurement range selection: yes
Maximum clamp opening width: 25 mm
Maximum diameter of cable measurable with the clamp: 25 mm
Beep: yes
Display range: 6000
Automatic shutdown: 15 min
Non-contact AC voltage detection NCV: yes
Measured peak value hold mode: yes
Returns & Warranty
Product returns
14-day right of withdrawal. Terms for consumers and business customers.
Return instructionsWarranty
All products come with manufacturer warranty as required by law.
We ship from Estonia






Delivery time depends on stock
This product has no reviews yet. Be the first to rate it.
Product description
The YATO TRUE RMS clamp multimeter YT-730933 is a measuring instrument designed for basic and precision measurements of electrical quantities. Its clamp can be used to measure AC and DC current from 10 mA–1000 A.
There is no need to interrupt the circuit or disconnect it from the power supply to measure current, and the clamp can measure higher current than conventional electrical measuring instruments.
The clamp must be closed around a single core or wire; closing it around a multicore cable without separating the cores may give an incorrect or zero reading.
Measurement capabilities
The device measures AC and DC voltage, AC and DC current, and resistance. It can also measure capacitance, frequency and temperature, perform a diode test, and check circuit continuity. The diode test current is IF 2 mA and the reverse voltage is UR 3,2 V. The device can also measure inrush current and detect phase.
TRUE RMS and DC measurement
TRUE RMS displays the true RMS value of AC voltage and current.
It provides a reading for sine waves as well as distorted sine, square and triangular waveforms.
This function is necessary, for example, in circuits with switched-mode power supplies, motor drives with frequency converters, and HVAC systems.
The TRUE RMS frequency range for AC voltage and current measurement is 40–1000 Hz.
For DC current measurement, the device uses a Hall sensor that measures magnetic field strength.
The Earth's magnetic field may cause a non-zero initial reading; use the REL button to zero the reading.
Voltage detection and measurement range selection
NCV detects AC voltage inductively and without contact, making it possible to detect voltage in an insulated wire and helping to identify the phase wire.
The LINE function detects AC voltage by contact, like a conventional voltage tester.
If the probe is inserted into an outlet opening and a phase is present, four dashes appear on the display, the indicator light turns on, and an intermittent beep sounds.
AUTO selects the measurement range automatically and is the device's default startup mode.
When measuring an unknown value, the device finds the appropriate range in a single measurement.
The RAN function allows the range to be changed manually.
When selecting the range manually, start with the highest range and work down to a more precise one, as selecting the wrong range may damage the device.
DATA HOLD keeps the measured value on the display.
Inrush current and measurement accuracy
The INR function measures inrush current with the clamp 80 ms after the device starts up.
Examples of measurement results with uncertainty: for an AC current reading of 30 A, 30 ± 0,85 A; for an AC voltage of 235 V, 235 ± 2,85 V; and for a DC voltage of 12 V, 12 ± 0,146 V.
The table of measurement range resolution and accuracy is in the user manual.
Display and construction
The display shows measurement results, and the probe leads have flexible, high-temperature-resistant silicone insulation.
The probes are 14 cm long, the lead length including the probes is 103 cm, and the lead diameter including insulation is 3,6 mm.
During the continuity test, a beep sounds when the resistance is below 50 Ω.
A storage bag is included.
The device has overload protection, and automatic shutdown can be disabled if desired.
Shipping & Delivery
We ship from Estonia






Delivery time depends on stock
Returns & Warranty
Product returns
14-day right of withdrawal. Terms for consumers and business customers.
Return instructionsWarranty
All products come with manufacturer warranty as required by law.
Reviews
This product has no reviews yet. Be the first to rate it.

YATO clamp multimeter TRUE RMS, 10 mA–1000 A
YT-730933